Showing all 6 results

Puncture Biopsy Cannulas

For biopsy and soft tissue sampling

  • axial-rotation-cut for very high tissue results
  • optimal guidance due to excellent 3-point fixation of inserted cannula
  • smooth guidance by special polishing – even when cannula is bended
  • with a protective tube for prevention of needlestick injuries and sterility – even with the closed and cocked instrument
  • contamination protection by extended plastic attachment which avoids the contact of the needle with the instrument
  • easy insertion of the cannula
  • Luer connection for aspiration or application of local anesthesia
  • notch length 19 mm
  • suitable for ultrasound or hand-guided biopsy
  • 1:1 graduated, every 5 cm a thicker line

 

Details with great effect:

  • precise insertion of the cannula
  • safer fixation of the cannula
  • smoother guidance of the cannula
  • increased power transmission between spring and cannula

 

REF PZN Diameter Length
6029.20 10397949 20 G / 0,90 mm 200 mm
6030.16 10267632 18 G / 1,20 mm 160 mm
6030.20 10267649 18 G / 1,20 mm 200 mm
6030.24 10267655 18 G / 1,20 mm 240 mm
6030.30 10267572 18 G / 1,20 mm 300 mm
6031.16 10267589 16 G / 1,65 mm 160 mm
6031.20 10267595 16 G / 1,65 mm 200 mm


The products presented here are a program extract, further information is available upon request.

Read more

For biopsy and soft tissue sampling

  • ready-to-use – no preparation and sterilisation necessary
  • very high spring tension for powerful puncture and excellent biopsy results
  • easy cocking
  • one-handed use
  • notch length 19 mm
  • 1:1 graduated, every 5 cm a thicker lin

 

* only available in Germany

REF Diameter Length
6055.16 18 G / 1,20 mm 160 mm
6055.20 18 G / 1,20 mm 200 mm
6055.25 18 G / 1,20 mm 250 mm


The products presented here are a program extract, further information is available upon request.

Read more

Fine Biopsy Needle

Cannula for fine-needle biopsy

  • high stability by Luer connection
  • between outer cannula and inner mandrin
  • inner mandrin with trocar-cut
  • flexible depth regulator for controlling penetration depth
  • 1:1 graduated from the tip, every 5 cm a thicker line
REF PZN Diameter Length
6065.20 09121136 21 G / 0,80 mm 200 mm

 


The products presented here are a program extract, further information is available upon request.

Read more

Cannula for percutaneous puncture

  • high stability by Luer connection between outer cannula and inner mandrin
  • inner mandrin with trocar-cut
  • flexible depth regulator for controlling penetration depth
  • 1:1 graduated from the tip, every 5 cm a thicker line
REF PZN Diameter Length for Biopsy Cannulas
6056.13 06438111 16 G / 1,65 mm 119 mm 18 G / 160 mm (REF 6030.16)

 


The products presented here are a program extract, further information is available upon request.

Read more

The innovation in the accurate biopsy.

Biopsy Device for biopsy and soft tissue sampling

  • high spring tension for powerful puncture and optimized tissue samples
  • triggers for automatic or semi-automatic sampling
  • time extensive release is not necessary due to special pressure point protection
  • excellent one-handed use
  • easy cocking
  • quiet application
  • opening of the cover by pushing the button
  • optional penetration depth 15 or 22 mm
  • status of the device is shown on the cocking indicator
  • customized application with »CORAZOR®« Puncture Biopsy Cannulas
REF
6020

 


The products presented here are a program extract, further information is available upon request.

Read more


TROKAR Puncture Biopsy Cannulas

For biopsy and soft tissue sampling

  • ready-to-use – no preparation and sterilisation necessary
  • very high spring tension for powerful puncture and excellent biopsy results
  • easy cocking
  • one-handed use
  • notch length 19 mm
  • 1:1 graduated, every 5 cm a thicker lin

 

* only available in Germany

REF Diameter Length
6055.16 18 G / 1,20 mm 160 mm
6055.20 18 G / 1,20 mm 200 mm
6055.25 18 G / 1,20 mm 250 mm

 


The products presented here are a program extract, further information is available upon request.